S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
94
•
In the following cases, this function cannot be used:
–
An analog remote control (optional) is connected.
–
Internal function F11 (Fine adjustment of welding conditions memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding condition with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special crater sequence) is set to "ON" (enabled);
–
Internal function F51 (Special crater repeat) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or "5" (Loading
welding condition).
)&XUUHQWLQFUHDVHDQGGHFUHDVHE\VLQJOHFOLFNLQJ
To increase/decrease the welding current by the torch switch operation, set the current increase/ decrease volume at single-
clicking. This function is available when the internal function F48 (Adjusting current with torch switch) is set to [ON].
•
Set the current increase/decrease volume by single-clicking in the range of -100 to 100 A.
)&XUUHQWLQFUHDVHDQGGHFUHDVHE\GRXEOHFOLFNLQJ
To increase/decrease the welding current by the torch switch operation, set the current increase/ decrease volume at
double-clicking. This function is available when the internal function F48 (Adjusting current with torch switch) is set to
[ON].
•
Set the current increase/decrease volume by double-clicking in the range of -100 to 100 A.
)6SHFLDOFUDWHUUHSHDW
In the sequence of main welding of the "CRATER-FILL ON (Repeat)" (during start input holding), the torch switch
operation can switch the welding and crater treatment repeatedly as many time as needed.
•
[ON]: Setting of "CRATER-FILL ON (Repeat)" is applied, and transits to the crater treatment by single-clicking of the
torch switch during the welding sequence (start input holding). It is available to return to the main welding as many
times as needed even after transit to the crater treatment by single-clicking of the torch switch.
When this function is enabled, "special crater (repeat)" is displayed in the HOME screen.
•
[OFF]: disables the function.
T I P S
• When this function is set to [ON], automatically the setting of "CRATER-FILL ON (Repeat)" is
selected, disabling other welding modes. (The CRATER-FILL menu does not work.)
• Single-clicking operation should be within 0.3 seconds.
• At the time of transition to crater, press the torch switch for at least 0.3 seconds.
• Welding method at crater treatment is the same as that of main welding.
Example:
In the setting examples of Initial welding current: 80 A; Main welding current: 100 A; and Crater current: 60 A, the
following diagram is available:
100 A
80 A
60 A
100 A
60 A
Press 0.3 sec. or more
100 A
60 A
Single
(within 0.3 sec.)
ON
OFF
Torch switch
Welding current
Crater-fil
㼘
Main welding
Initial condition
Crater-fil
㼘
Crater-fil
㼘
Main
welding
Main
welding
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...