99
Chapter 6
W
elding Condition
O
PERATION
OF
A
NALOG
R
EMOTE
C
ONTROL
(O
PTIONAL
)
W
ELDING
C
ONDITION
C
HAPTER
6
2SHUDWLRQRI$QDORJ5HPRWH&RQWURO2SWLRQDO
This section explains the functions of knobs and buttons arranged for the analog remote controller (optional) as well as
their operation.
Since the setting at the analog remote control is preferred when connected, it is not possible to set this condition on the
operation panel of welding power source. (The initial condition and crater condition can be set on the operation panel.)
T I P S
• In connecting (or removing) the analog remote control to (or from) the welding power source, turn OFF
the power switch of the welding power source.
• The analog remote control is automatically recognized after being connected to the analog remote
control and turning ON the power switch.
No.
Name
Function
1
Welding current adjustment knob
Set the welding current. The set value is displayed on the left digital meter at the welding power
source side.
2
Welding voltage adjustment knob
Set the welding voltage. The set value is displayed on the right digital meter at the welding power
source side.
•
< SYNERGIC adjustment >
Optimum welding voltage according to the welding current is automatically set, and fine
adjustment is available for the set welding voltage.
Align the welding voltage adjustment knob to the center ("
●
" mark), and adjust the voltage
with the position as the standard.
•
< INDIVIDUAL adjustment >
The welding voltage can be individually adjusted without being influenced by the welding
current.
3
Inching button
Feeds the wire. (
5.4
-
Wire Inching)
During when the button is pressed, the wire feeding is carried out.
Wire feed speed can be adjusted by the welding current adjustment knob while pressing the
inching button.
4
Scale plate (*1)
Replace the scale plate for analog remote control (
6.7.2.8
-
F9: Analog remote control scale)
when using the optional analog remote control. Note that the scale of analog remote control as
well as the scale plate to be used depends on the rated output current of the welding power
source. (Above diagram shows an example with 350 A)
•
350 A: 350/200
•
500 A: 500/350/200
5
Switch knob
Operated to use the functions selected in internal function F2. (
6.7.2.8
-
F2: Switching
functions with remote control)
6
Fixing screw
To replace the scale plate, turn the screw counter clockwise, and remove them.
*1: For adjustment of low current region when using a thin wire, etc., using the accessory scale plate with full scale of 200 A allows
fine adjustment. To use this scale plates, set the internal function F9 function. (
6.7.2.8
-
F9: Analog remote control scale)
>㸯@
>㸰@
>㸱@
1
3
5
6
4
2
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...