37
Chapter 4
Connection
G
ROUNDING
AND
C
ONNECTION
OF
I
NPUT
P
OWER
S
UPPLY
C
ONNECTION
C
HAPTER
4
*URXQGLQJDQG&RQQHFWLRQRI,QSXW3RZHU6XSSO\
This section explains the procedure for performing grounding work, connecting the welding power source and input
power supply (power supply at facility side).
1.
Check that input power is turned off with the disconnect switch connected to the welding power source.
2.
Perform grounding work for welding power source.
●
Grounding cable: AWG6 (13.3 mm
2
) with 0.4"
Ʒ
(10 mm
Ʒ
) terminal×1
B
The grounding cable is a striped pattern in yellow and green or solid green.
3.
Connect the power cables (3 pcs) to the output terminals of power source at facility side.
●
Input cable: AWG6 (13.3 mm
2
) with 0.4"
Ʒ
(10 mm
Ʒ
) terminal×3
Grounding and connection of input power supply is complete. Procedure is followed by “4.4
-
Confirmation of
Connection”.
When the welding power source is used in a humid environment such as construction
site, or location with highly conducting material such as steel plate or on steel structure,
install a leakage breaker.
Otherwise, electric shock due to leakage of electricity may occur.
Be sure to install a switch with fuse or a circuit breaker to the input side of each welding
power source.
Otherwise, electric shock and fire due to overcurrent or damage to the welding power
source may occur.
If the welding power source which is not grounded is used, voltage will be generated in
the case through the capacitor between the welding power source input circuit and the
case or floating capacity (electrostatic capacity naturally generated between the input
conductor and the case metal). If you touch the case, you may suffer from electric
shock. Be sure to ground the case of the welding power source.
Be sure to connect the input cable (3 pcs) in the correct position and securely tighten
them to the terminal block.
Improper connection may cause electric shock, fire and damage to the welding power
source.
Mount a switch with fuse or a circuit breaker on
each welding power source.
Green/yellow or solid green cable for
grounding cable
Green/yellow or
solid green cable
for grounding cable
Connect the red (1) and
white (2) cable to the output
terminals of power source at
facility side.
Isolates the top of black (1)
cable to fix it to the cable
conductor with an insulation
tape.
•
WB-M352
Input cable
Single phase connection
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...