95
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
•
In the following cases, this function cannot be used:
–
Internal function F11 (Fine adjustment of welding conditions memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding condition with remote control) is set to "ON" (enabled);
–
Internal function F45 (Special crater sequence) is set to "ON" (enabled);
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Either of the internal functions F29 to F32 (External input terminal setting) is set to either "4" (Start) or "5" (Loading
welding condition).
)'DWDW\SHRIGDWDORJIXQFWLRQ
This function enables to select data to save when using the data log function.
The patterns of data which can be saved are as shown in the below table.
For data log function; (
7.3
-
Data Backup (Utilization of data)).
)6DPSOLQJVSHHGRIGDWDORJIXQFWLRQ
Selects the data sampling interval in using data log function.
The relationship between the setting value and the data sampling is as follows:
For data log function; (
7.3
-
Data Backup (Utilization of data)).
)7DFNVWDUWSURFHVV
This function enables to start the wire feeding speed with the normal feeding speed without slow-down after the welding
completion. (which enables the tack welding of less transition time)
•
[ON]: Pressing the torch switch within 0.5 seconds after the welding completion can start it with the normal feeding
speed. (The wire feeding speed at this time is not exceeding 197 IPM (5 m/min).)
•
[OFF]: disables the function.
)WR)5HVHUYHG
Used in connection with the automatic machines of other manufacturers.
)6HWWLQJFKDQJHRIFXUUHQWYDOXHLQLWLDOFRQGLWLRQFUDWHUFRQGLWLRQ
When “CRATER ON” is selected, the current value of the initial condition and the crater condition can be set in percentage
based on the current value of the welding condition.
•
[ON]: enables the function.
Set the current value of the initial condition with F68, and set the current value of the crater condition with F69.
•
[OFF]: disables the function.
Setting
Welding current
Welding current
Welding voltage
Welding voltage
Wire feed speed
Wire feed speed
(Command value)
(Detected value)
(Command value)
(Detected value)
(Command value)
(Detected value)
0
-
-
-
-
-
-
1
-
Storable
-
Storable
-
Storable
2
Storable
-
Storable
-
Storable
-
3
Storable
Storable
-
Storable
-
-
4
Storable
Storable
-
-
-
Storable
5
-
Storable
Storable
Storable
-
-
6
-
-
Storable
Storable
-
Storable
7
-
Storable
-
-
Storable
Storable
8
-
-
-
Storable
Storable
Storable
Setting Sampling
interval
1
10 ms
2
100 ms
3
1 s
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...