93
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
•
In the following cases, this function cannot be used:
–
Internal function F11 (Fine adjustment of welding conditions memory) is set to "1" to "30" (enabled);
–
Internal function F44 (Reading welding condition with remote control) is set to "ON" (enabled);
–
Internal function F48 (Adjusting current with torch switch) is set to "ON" (enabled); or
–
Internal function F51 (Special crater repeat) is set to "ON" (enabled); or
–
Either of the internal function F29 to F32 (External input terminal setting) is set to "5" (Loading welding condition).
)$GMXVWLQJFXUUHQWZLWKWRUFKVZLWFK
Increases/decreases the welding current by the torch switch operation.
•
[ON]: the setting of "CRATER-FILL ON" is selected, enabling to increase or decrease welding current by single-
clicking or double-clicking the torch switch in the period of welding condition (during start input holding)
•
If this function is enabled, "ADJUST.CURRENT by TS" is displayed in the HOME screen, enabling the internal
functions F49 and F50.
•
Set the increase/decrease current volume through F49 (Current increase and decrease by single-clicking) and F50
(Current increase and decrease by double-clicking).
•
[OFF]: disables the function.
T I P S
• When the internal function F45 is set to [ON], automatically the setting of "CRATER-FILL ON" is
selected, disabling other welding modes. (The CRATER-FILL menu does not work.)
• Setting for current increase and decrease is available for both single-clicking and double-clicking.
• Single-clicking or double-clicking operation should be within 0.3 seconds.
• At the time of transition to crater, press the torch switch for at least 0.3 seconds.
• Welding method at crater treatment is the same as that of main welding.
Example:
In the setting examples of Crater setting: ON; Initial condition: OFF; Welding current: 100 A; Crater current: 60 A; F48:
"ON"; F49:"-10"; and F50: "20", the following diagram is available:
100 A
90 A
80 A
100 A
90 A
110 A
100 A
60 A
Press 0.3 sec. or more
Single
(within 0.3 sec.)
Double
(within 0.3 sec.
x 2 times)
ON
OFF
Within
0.3 sec.
Torch switch
Welding current
Crater-fil
㼘
Main welding
Within
0.3 sec.
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...