,QWHUQDOIXQFWLRQ
Details of internal function (
6.7
-
Setting Internal Functions)
The functions with check mark (
9
) on the Memory row can be stored with the welding conditions.
No.
Function Name
Setting range
Initial value
Explanation
Memory
F1
Standard/Extended
cable mode
OFF/ON
OFF
Sets the waveform control mode for voltage detection
when using the welding power source in the STANDARD
mode.
OFF: STANDARD mode (standard mode)
ON: Extended cable mode (extended mode of power
cable)
-
F2
Switching functions with remote
control
0/1/2/3/4/5/6
0
Sets the functions to be allocated to the switching knob
of the analog remote control.
0: No functions
1: Crater setting
2: Gas check
3: Constant penetration
4: Tack Start
5: Read out of welding conditions
6: No functions
9
F3
No function
OFF (fixed)
OFF
No functions are provided.
-
F4
Auto/Semi-auto mode
0/1/2/3/4
0
Switches the I/O settings of the welding power source:
0: Semi-automatic machine
1: Automatic machine 1
2: Automatic machine 2
3: Almega (OTC’s robots) specification
4: Almega (OTC’s robots) specification (for high speed
communication)
-
F5
Maximum external command
voltage
10.0/14.0/15.0
15.0 (V)
Sets the maximum value of voltage supplied when
current/voltage command is externally input.
-
F6
Up slope time
0.0 to 10.0
0.0 (s)
Sets the slope time from the initial condition to the
welding condition.
9
F7
Down slope time
0.0 to 10.0
0.0 (s)
Sets the slope time from the welding condition to the
crater condition.
9
F8
Welding result display time
0 to 60
20 (s)
Sets the display time for the current/voltage after
completion of welding.
-
F9
Analog remote control scale
200/350
(*1)
350 (A)
Configures the settings of scale plate of the analog
remote control.
-
200/350/500
(*2)
500 (A)
F10
Motor over current detection
level
20 to 150
70 (%)
Sets the over current warning level for the rated current
of the wire feed motor.
-
F11
Fine adjustment of welding
conditions memory
OFF/1 to 30
OFF
Allows fine tuning the current and voltage of welding
conditions stored on the memory using the analog
remote control.
OFF: No fine adjustment
1 to 30 (%): Fine adjustment is performed (Maximum
adjustment range at this time can be set in percentage)
-
F12
Operation time of water-cooled
pump
20 to 60/ON
ON
Sets the operation time of water-cooled pump after
welding ends.
Set the time in the range of 20 to 60 minutes or set to
ON (always ON ).
-
F13
Turbo start
OFF/ON
ON
Set effective and ineffective of the turbo start function.
OFF: ineffective
ON: effective
-
F14
Start control time adjustment
-50 to 50
0 (%)
Adjusts the control time of current at the time of start.
-
F15
Start control current adjustment
-100 to 100
0 (A)
Adjusts the control of current at the time of start.
-
F16
Slow-down speed adjustment
-39 to 39
(-1.0 to 1.0)
0.0 [IPM
(m/min)]
Adjusts slowdown speed.
9
F17
Anti-stick time adjustment
-50 to 50
0 (10 ms)
Allows fine tuning meltage of the wire at the end of
welding based on the anti-stick process time.
9
F18
Anti-stick voltage adjustment
-9.9 to 9.9
0.0 (V)
Allows fine tuning meltage of the wire at the end of
welding based on the anti-stick process voltage.
9
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...