91
Chapter 6
W
elding Condition
S
ETTING
I
NTERNAL
F
UNCTIONS
W
ELDING
C
ONDITION
C
HAPTER
6
T I P S
• Use the voltage detection cable (optionally available) when the total length of the extension cable is
99 ft (30 m) or longer.
• When using wire feeder CM-7403, water-cooled welding torch cannot be used. Accordingly, arc voltage
direct detection switch cannot be activated even with this function set to "1".
• When using a reverse-polarity wire, set this function to "2".
))2XWSXWFXUUHQWJDLQDGMXVWPHQW
If there is difference between the current value indicated on the digital meter and the actual output current value, the
difference can be calibrated through adjustment of F39/F40.
The output current value that can be changed by F39 is [1], which is equivalent to 1A. The value that can be changed by
F40 is about 0.01A, which is equivalent to [0.01].
This function can be adjusted only in the "calibration mode". For details, refer to "7.6
-
Calibration Mode".
NOTE
• Do not carelessly change the setting of this function.
))2XWSXWYROWDJHJDLQDGMXVWPHQW
If there is difference between the voltage value indicated on the digital meter and the actual output voltage value, the
difference can be calibrated through adjustment of F41/F42. The output voltage value that can be changed by F41 is [0.1],
which is equivalent to about 0.01 V. The value that can be changed by F42 is about [0.01], which is equivalent to about 0.01
V. This function can be adjusted only in the "calibration mode". For details, refer to "7.6
-
Calibration Mode".
NOTE
• Do not carelessly change the setting of this function.
)&$1,'
When multiple welding power sources are connected with a PC monitoring system, set ID for CAN.
)5HDGLQJZHOGLQJFRQGLWLRQVZLWKUHPRWHFRQWURO
Sets whether to read the welding condition registered to the memory by the analog remote control (optional) or not. This
function is effective when the internal function F4 (Auto/Semi-auto mode) is set to "0".
•
[ON]: reads the welding condition by the analog remote control (optional)
–
Setting the welding current setting knob on the analog remote control to 1-10 of the scale can read out the
conditions stored to the JOB No. 1-10.
–
By the welding voltage setting knob, fine adjustment of the welding voltage of the condition read out is available.
(% adjustment)
Adjust the voltage value based on the center of welding voltage setting knob. To increase the welding voltage,
turn the knob clockwise and to reduce the welding voltage, turn the knob counterclockwise.
The fine adjustment range for welding voltage is up to ±20 %.
Example:
The right figure shows an example when the JOB No. "3" is read out and the
welding voltage is the condition stored on the memory (no fine
adjustment).
1
4
5
7
8
9
10
3
2
6
350
50
100
200
250
150
300
28
14
18
20
24
30
36
16
22
26
32
34
[
P
]
[ Q]
[ R]
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...