65
Chapter 6
W
elding Condition
M
EMORY
F
UNCTION
OF
W
ELDING
C
ONDITIONS
W
ELDING
C
ONDITION
C
HAPTER
6
0HPRU\)XQFWLRQRI:HOGLQJ&RQGLWLRQV
This section explains the memory function of welding conditions.
The welding power source is equipped with the function to register the welding conditions and reads them out for use.
The number of welding conditions that are able to be registered are 100 at maximum. Single welding condition can contain
the following information at registration:
•
Welding mode selected by the keys on operation panel (Shield gas/Wire/Crater/Penetration control, etc.)
•
Welding current/voltage for each welding sequence (
6.6.3
-
Setting welding parameter)
•
Part of internal function (
6.1.3
-
Internal function)
NOTE
• When the analog remote control (optional) is connected to the machine, even if the stored welding
condition is read, the set values of the analog remote control apply to the welding current and welding
voltage of welding condition.
T I P S
• Use of the internal function (F44) enables to read out the registered welding condition by the analog
remote control (optional). (
6.7
-
Setting Internal Functions)
• Use of the internal function (F11) enables to finely adjust the current/voltage values read out from the
memory by the analog remote control (optional). (
6.7
-
Setting Internal Functions)
0HPRU\UHJLVWUDWLRQRIZHOGLQJFRQGLWLRQV
This section explains how to register the current welding condition set on the operation panel to the memory.
1.
Display “SAVE JOB” in the MENU screen.
CAUTION
• The welding conditions (electronic data) stored by this function are susceptible to
occurrence of static electricity, impact, repair, etc., and there is a possibility that the stored
contents may be changed or lost. BE SURE TO MAKE A COPY FOR IMPORTANT DATA.
• Please note that OTC will not be liable for any alteration or loss of electronic information.
• The memory function of welding condition is not available if the welding method is "DC TIG"
or "DC STICK".
●
Turn the screen operation knob and point the cursor to
SAVE JOB.
●
Press the screen operation knob.
⇒
The JOB No. (registration No.) is displayed on the right
digital meter in a flashing mode, and the LED of JOB lights
up.
⇒
On the left digital meter, the setting value of the welding
current registered to the JOB No. if any is displayed (if
there is no registration, "- - - -" is displayed), and the "A"
LED lights up.
⇒
If the welding condition corresponding to the selected JOB
No. is not registered, “no data” is displayed on the LCD
panel, and “- - - -” will flash on the left digital meter.
)81&7,216
/2$'-2%
6$9(-2%
:(/'021,725
.(</2&.㸸
%$&.83
0(18
2))
㸭21
+20(
6(/(&7
(17(5
Содержание Welbee M350 II
Страница 1: ...Welbee M350 II M500 II OWNER S MANUAL July 2021 Manual No P30355 1 DAIHEN Corporation...
Страница 139: ...137 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 6FKHPDWLF GLDJUDP WB M352...
Страница 140: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 138...
Страница 141: ...139 Chapter 10 Reference Materials REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 WB M502...
Страница 142: ...REFERENCE DRAWING REFERENCE MATERIALS CHAPTER 10 140...