176
Process and Application Parameters [300]
Section 11-3
To set the load below which the SX-F goes into load dependent field weaken-
ing operation.
Communication information
When set to OFF, the load dependent field weakening function is switched off.
CRIO N Input function [3AG]
Set the functon of CRIO/Crane I/O interface N (null) input.
Communication information
Brake Acknowledge via Crane I/O has priority (and overrules) Brake Acknowl-
edge via control board I/O ([521 DigIn1] - [528 DigIn8]).
Fieldbus format
Long, 1=0.001 s
Modbus format
EInt
Default:
Off
Off
0
Off
1–100
1–
100
1% – 100%
Modbus Instance no/
DeviceNet no:
43193
Profibus slot/index
169/97
EtherCAT index (hex)
4c79
Fieldbus format
Long, 1=1%
Modbus format
EInt
Default:
Zero Pos
Off
0
N input not used
Zero pos
1
N input used for joystick zero position indication
Brk Ackn
2
N input used for Brake Acknowledge.
Modbus Instance no/
DeviceNet no:
43194
Profibus slot/index
169/98
EtherCAT index (hex)
4c7a
Fieldbus format
UInt
Modbus format
UInt
Off
A
3AG Crane N Func
Stp
Zero pos
A
Содержание SX-F
Страница 2: ......
Страница 14: ...6 Table of contents...
Страница 20: ...12 Glossary Section 1 6...
Страница 32: ...24 Cabinet mounting Section 2 3...
Страница 58: ...50 Connecting options Section 5 6...
Страница 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Страница 74: ...66 EMC standards Section 8 1...
Страница 266: ...258 System Data 900 Section 11 9...
Страница 274: ...266 Maintenance Section 12 3...
Страница 284: ...276 Liquid cooling Section 13 12...