249
View Operation/Status [700]
Section 11-7
Analogue Input Status [726]
Indicates the status of the analogue inputs 3 and 4.
Fig. 114 Analogue input status
Communication information
Analogue Output Status [727]
Indicates the status of the analogue outputs. Fig. 115. E.g. if 4-20 mA output
is used, the value 20% equals to 4 mA.
Fig. 115 Analogue output status
Communication information
The first row indicates the Analogue outputs.
1: AnOut 1
2: AnOut 2
Reading downwards from the first row to the second row the status of the
belonging output is shown in %:
-100% AnOut1 has a negative 100% output value
65% AnOut1 has a 65% output value
The example in Fig. 115 indicates that both the Analogue outputs are active.
Note
The shown percentages are absolute values based on the full range/scale of
the in- our output; so related to either 0–10 V or 0–20 mA.
I/O board Status [728] - [72A]
Indicates the status for the additional I/O on option boards 1 (B1), 2 (B2) and
3 (B3).
Modbus Instance no/
DeviceNet no:
31021, 31022
Profibus slot/index
121/165, 121/166
EtherCAT index (hex)
23fd, 23fe
Fieldbus format
Long, 1=1%
Modbus format
EInt
Modbus Instance no/
DeviceNet no:
31023, 31024
Profibus slot/index
121/167, 121/168
EtherCAT index (hex)
23ff, 2400
Fieldbus format
Long, 1=1%
Modbus format
EInt
4
Stp
-100% 65%
2
Stp
-100% 65%
728 IO B1
Stp
RE000 DI10
Содержание SX-F
Страница 2: ......
Страница 14: ...6 Table of contents...
Страница 20: ...12 Glossary Section 1 6...
Страница 32: ...24 Cabinet mounting Section 2 3...
Страница 58: ...50 Connecting options Section 5 6...
Страница 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Страница 74: ...66 EMC standards Section 8 1...
Страница 266: ...258 System Data 900 Section 11 9...
Страница 274: ...266 Maintenance Section 12 3...
Страница 284: ...276 Liquid cooling Section 13 12...