174
Process and Application Parameters [300]
Section 11-3
To set the speed used when crawling (min. speed) during lowering operation.
Activated with input A2, Crawl L/L=Start in negative speed direction.
Communication information
To set the speed used when the input B1, Speed 2 on the Crane option board
is active.
Communication information
To set the speed used when the input B2, Speed 3 on the Crane option board
is active.
Communication information
Fieldbus format
Int, 1=1 rpm
Modbus format
Int, 1=1 rpm
Default:
0
Range:
0 – 4 x Sync speed
Modbus Instance no/
DeviceNet no:
43190
Profibus slot/index
169/94
EtherCAT index (hex)
4c76
Fieldbus format
Int, 1=1 rpm
Modbus format
Int, 1=1 rpm
Default:
0
Range:
0 – 4 x Sync speed
Modbus Instance no/
DeviceNet no:
43186
Profibus slot/index
169/90
EtherCAT index (hex)
4c72
Fieldbus format
Int, 1=1 rpm
Modbus format
Int, 1=1 rpm
Default:
0
Range:
0 – 4 x Motor Sync speed
Modbus Instance no/
DeviceNet no:
43187
Profibus slot/index
169/91
EtherCAT index (hex)
4c73
rpm
A
3A8 Speed 2
Stp
rpm
A
3A9 Speed 3
Stp
rpm
A
Содержание SX-F
Страница 2: ......
Страница 14: ...6 Table of contents...
Страница 20: ...12 Glossary Section 1 6...
Страница 32: ...24 Cabinet mounting Section 2 3...
Страница 58: ...50 Connecting options Section 5 6...
Страница 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Страница 74: ...66 EMC standards Section 8 1...
Страница 266: ...258 System Data 900 Section 11 9...
Страница 274: ...266 Maintenance Section 12 3...
Страница 284: ...276 Liquid cooling Section 13 12...