31
Connect motor and mains cables
Section 3-3
3-3
Connect motor and mains cables
SX-D4045-EF to SX-D4132-EF and SX-D6090-EF to SX-
D6160-EF
To simplify the connection of thick motor and mains cables to the VSD model
SX-D4045-EF to SX-D4132-EF and SX-D6090-EF to SX-D6160-EF the cable
interface plate can be removed.
Fig. 27 Connecting motor and mains cables
1.
Remove the cable interface plate from the VSD housing.
2.
Put the cables through the glands.
3.
Strip the cable according to Table 8.
4.
Connect the stripped cables to the respective mains/motor terminal.
5.
Fix the clamps on appropriate place and tighten the cable in the clamp with
good electrical contact to the cable screen.
6.
Put the cable interface plate in place and secure with the fixing screws.
Cable interface
Clamps for screening
Motor cable
Mains cable
DC+, DC-, R (optional)