Main Setup [200]
Section 11-2
External Motor Trip Type [25S]
Select the preferred way to react to an alarm trip.
Communication information
Liquid cooling low level [25T]
Delay time starts counting when the fault disappears. When the time delay
has elapsed, the alarm will be reset if the function is active.
Communication information
Liquid Cooling Low level Trip Type [25U]
Select the preferred way to react to an alarm trip.
EtherCAT index (hex)
4c19
Fieldbus format
Long, 1=1 s
Modbus format
EInt
Default:
Trip
Selection:
Same as menu [25B]
Modbus Instance no/
DeviceNet no:
43098
Profibus slot/index
168/240
EtherCAT index (hex)
4c1a
Fieldbus format
UInt
Modbus format
UInt
Default:
Off
Off
0
Off
1–3600
1–
3600
1–3600 s
Modbus Instance no/
DeviceNet no:
43099
Profibus slot/index
169/3
EtherCAT index (hex)
4c1b
Fieldbus format
Long, 1=1 s
Modbus format
EInt
Default:
Trip
Selection:
Same as menu [25B]
Trip
A
25T LC Level
Stp
Off
A
Trip
A