43
Inputs configuration with the switches
Section 5-3
Note
N/C is opened when the relay is active and N/O is closed when the relay is
active.
5-3
Inputs configuration
with the switches
The switches S1 to S4 are used to set the input configuration for the 4 ana-
logue inputs AnIn1, AnIn2, AnIn3 and AnIn4 as described in table 17. See Fig.
35 for the location of the switches.
Note
Scaling and offset of AnIn1 - AnIn4 can be configured using the software. See
menus [512], [515], [518] and [51B] in section 11-5, page 187.
Note
The 2 analogue outputs AnOut 1 and AnOut 2 can be configured using the
software. See menu [530] section 11-5-3, page 201.
51
COM 3
Relay 3 output
Off
52
N/O 3
Table 16 Control signals
Terminal
Name
Function (Default)
Table 17 Switch settings
Input
Signal type
Switch
AnIn1
Voltage
S1
Current (default)
S1
AnIn2
Voltage
S2
Current (default)
S2
AnIn3
Voltage
S3
Current (default)
S3
AnIn4
Voltage
S4
Current (default)
S4
U
I
U
I
U
I
U
I
U
I
U
I
U
I
U
I