235
Logical Functions and Timers [600]
Section 11-6
Selects the third comparator for the logic Z function.
Communication information
11-6-4 Timer1 [640]
The Timer functions can be used as a delay timer or as an interval with sepa-
rate On and Off times (alternate mode). In delay mode, the output signal T1Q
becomes high if the set delay time is expired. See Fig. 108.
Fig. 108
In alternate mode, the output signal T1Q will switch automatically from high to
low etc. according to the set interval times. See Fig. 109.
The output signal can be programmed to the digital or relay outputs used in
logic functions [620] and [630], or as a virtual connection source [560].
Note
The actual timers are common for all parameter sets. If the actual set is
changed, the timer functionality [641] to [645] will change according set
settings but the timer value will stay unchanged. So initialization of the timer
might differ for a set change compared to normal triggering of a timer.
Fig. 109
Default:
CD1
Selection:
Same as menu [621]
Modbus Instance no/
DeviceNet no:
43425
Profibus slot/index
170/74
EtherCAT index (hex)
4d61
Fieldbus format
UInt
Modbus format
UInt
635 Z Comp 3
Stp
CD1
A
Timer1 Trig
T1Q
Timer1 delay
T1
T2
T1
T2
Timer1 Trig
T1Q
Содержание SX-F
Страница 2: ......
Страница 14: ...6 Table of contents...
Страница 20: ...12 Glossary Section 1 6...
Страница 32: ...24 Cabinet mounting Section 2 3...
Страница 58: ...50 Connecting options Section 5 6...
Страница 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Страница 74: ...66 EMC standards Section 8 1...
Страница 266: ...258 System Data 900 Section 11 9...
Страница 274: ...266 Maintenance Section 12 3...
Страница 284: ...276 Liquid cooling Section 13 12...