245
View Operation/Status [700]
Section 11-7
11-7-2 Status [720]
Indicates the overall status of the variable speed drive.
Fig. 110 VSD status
Example: “A/Key/Rem/TL”
This means:
A: Parameter Set A is active.
Key: Reference value comes from the keyboard (CP).
Rem: Run/Stop commands come from terminals 1-22.
TL: Torque Limit active.
Communication information
Description of communication format
Integer values and bits used
Display position
Status
Value
1
Parameter Set
A,B,C,D
222
Source of reference
value
-Key (keyboard)
-Rem (remote)
-Com (Serial comm.)
-Opt (option)
333
Source of Run/Stop/
Reset command
-Key (keyboard)
-Rem (remote)
-Com (Serial comm.)
-Opt (option)
44
Limit functions
-TL (Torque Limit)
-SL (Speed Limit)
-CL (Current Limit)
-VL (Voltage Limit)
- - - -No limit active
Modbus Instance no/
DeviceNet no:
31015
Profibus slot/index
121/159
EtherCAT index (hex)
23f7
Fieldbus format
UInt
Modbus format
UInt
Bit
Integer representation
1-0
Active Parameter set, where 0=A, 1=B, 2=C, 3=D
4-2
Source of Reference control value, where 0=Rem, 1=Key, 2=Com, 3=Option
7-5
Source of Run/Stop/Reset command, where 0=Rem, 1=Key, 2=Com,
3=Option
15-8
Active limit functions, where 0=No limit, 1=VL, 2=SL, 3=CL, 4=TL
721 VSD Status
Stp 1/222/333/44
Содержание SX-F
Страница 2: ......
Страница 14: ...6 Table of contents...
Страница 20: ...12 Glossary Section 1 6...
Страница 32: ...24 Cabinet mounting Section 2 3...
Страница 58: ...50 Connecting options Section 5 6...
Страница 72: ...64 Load Monitor and Process Protection 400 Section 7 5...
Страница 74: ...66 EMC standards Section 8 1...
Страница 266: ...258 System Data 900 Section 11 9...
Страница 274: ...266 Maintenance Section 12 3...
Страница 284: ...276 Liquid cooling Section 13 12...