41
Setup Procedure
Section 3-1
The SP and alarm settings are made for the channels allocated in the
group settings. SP and alarm settings made for unusable channels will not
be enabled.
The following table shows the Set Point, Alarm Value 1, and Heater Burn-
out Detection settings for each channel for this example.
9.
Perform tuning for gradient temperature control.
Tuning for gradient temperature control is called gradient tuning (GT). GT
is executed and stopped for the HFU.
GT is executed when all groups are in STOP and AUTO modes. GT can
also be executed for individual groups.
a.
Check that all groups are in STOP and AUTO modes.
Read the channel status of the initial channel for each group and check
that bit 0 (RUN/STOP) is ON (STOP) and that bit 1 (AUTO/MANUAL)
is OFF (AUTO).
If any group does not satisfy these conditions, execute operation com-
Variable
type
Address
Parameter
Setting
value
D0 (90)
0100
Bank 0 Set Point - CH1
200
Group 1
0200
Bank 0 Set Point - CH2
200
0300
Bank 0 Set Point - CH3
200
0500
Bank 0 Set Point - CH5
200
Group 2
0600
Bank 0 Set Point - CH6
200
0700
Bank 0 Set Point - CH7
200
010D
Bank 0 Alarm Value - CH1
230
Group 1
020D
Bank 0 Alarm Value - CH2
230
030D
Bank 0 Alarm Value - CH3
230
050D
Bank 0 Alarm Value - CH5
230
Group 2
060D
Bank 0 Alarm Value - CH6
230
070D
Bank 0 Alarm Value - CH7
230
D6 (96)
0100
Heater Burnout Detection - CH1 5.0 A
Group 1
0200
Heater Burnout Detection - CH2 5.0 A
0300
Heater Burnout Detection - CH3 5.0 A
0500
Heater Burnout Detection - CH5 5.0 A
Group 2
0600
Heater Burnout Detection - CH6 5.0 A
0700
Heater Burnout Detection - CH7 5.0 A
H
F
U
E
D
U
0 1 2
3
4
5
6
TC2
CH1
CH2
TC2 TC2 TC2 TC2 TC2
CH3 CH6 CH9 CH11 CH14
CH5 CH7 CH10 CH13 CH15
Содержание EJ1G
Страница 1: ...USER S MANUAL Modular Temperature Controllers for Gradient Temperature Control EJ1G Cat No H143 E1 01 ...
Страница 3: ...iv ...
Страница 17: ...xviii ...
Страница 21: ...xxii ...
Страница 53: ...32 Unit Configuration Examples Section 2 4 ...
Страница 69: ...48 Changing SPs During Operation Section 3 3 ...
Страница 81: ...60 Other Functions Section 4 5 ...
Страница 145: ...124 Other HFU Functions Section 5 7 ...
Страница 167: ...146 Detailed Description of Services Section 6 4 ...
Страница 189: ...168 Determining the Error from the Current Situation for Heater Burnout Alarm Errors Section 7 8 ...
Страница 229: ...208 Parameters That Can Be Allocated for Programless Communications Appendix ...
Страница 237: ......