114
Programless Communications
Section 5-6
• Multi Action
Operation of writing any parameters in the download area settings that
have changed from the previous values is performed continuously.
• Stop Operation
Operation is stopped after a series of operations has been completed.
Note (1) Always set the Setting Change Request Bits last. If the Setting
Change Request Bits are set before the set value is changed, an
unexpected value will be written.
(2) All programless download parameters will be updated when the
Setting Change Request Bits are set. If set values are not the
same in EJ1G and PLC memory, e.g., when the power is turned
ON or the bank is changed, always change the values in PLC
memory first and then set the Setting Change Request Bits.
Upload Area
Download Area
Value
0002
Operation Command
Response
Bits
Address
Value
Address
m+0
m+1
m+2
m+4
···
n+0
n+1
n+2
n+4
Operation Command
Request Bits
YYYY
Monitor value
Communications
Status
m+3
n+3
Operation
Command Code
Read Response
Bits
Read Request Bits
0002
PLC
EJ1G
HFU
TC4/TC2
YYYY
1. The Setting Change Request
Bits are set by the PLC.
2. The EJ1G sets the Setting
Change Response Bits.
3. The EJ1G repeatedly
reads the set values.
Upload Area
Download Area
Value
0000
Operation Command
Response Bits
Address
Value
Address
m+0
m+1
m+2
m+4
···
n+0
n+1
n+2
n+4
Operation Command
Request Bits
YYYY
Monitor value
Communications
Status
m+3
n+3
Operation
Command Code
Read Response
Bits
Read Request Bits
0000
PLC
2. The EJ1G clears the Setting
Change Response Bits.
1. The Setting Change Request
Bits are cleared by the PLC.
Содержание EJ1G
Страница 1: ...USER S MANUAL Modular Temperature Controllers for Gradient Temperature Control EJ1G Cat No H143 E1 01 ...
Страница 3: ...iv ...
Страница 17: ...xviii ...
Страница 21: ...xxii ...
Страница 53: ...32 Unit Configuration Examples Section 2 4 ...
Страница 69: ...48 Changing SPs During Operation Section 3 3 ...
Страница 81: ...60 Other Functions Section 4 5 ...
Страница 145: ...124 Other HFU Functions Section 5 7 ...
Страница 167: ...146 Detailed Description of Services Section 6 4 ...
Страница 189: ...168 Determining the Error from the Current Situation for Heater Burnout Alarm Errors Section 7 8 ...
Страница 229: ...208 Parameters That Can Be Allocated for Programless Communications Appendix ...
Страница 237: ......