OmniTek OTR 1001 User Guide, v3.1
N-9
The test sequence contains many elements that are useful for testing and analysing the
performance of a video system, however for the purposes of the audio/video delay measurement
it has two characteristics that are of special importance – an embedded audio tone (in the case of
the PCM-only sequence this tone needs to be added when the sequence is run) and a binary
frame count displayed in the top left-hand corner of each frame as a sequence of yellow squares.
When the clock hand reaches the top (frame 0), an
audio pulse is generated for 1 frame duration
This gives a binary count of
the test sequence
Figure N-9:
OmniTek Test Sequence
The Analyzer software extracts the binary frame count from the input video image. It also
detects the embedded audio tone. The relative timing of the audio tone to the first video frame in
the sequence indicates the delay between audio and video components.
Playing the Test Sequence
The supplied test sequences can only be played by the generator of an OmniTek OTM, OTR or
LAB system. However, the output from the Generator can then be recorded on a recording
device that also records blanking – e.g. a tape or disk recorder – and that recording subsequently
used in place of OmniTek system.
Control Panel
Mouse & Keyboard
To run the test sequence on an OTR 1001:
(
Note:
Equivalent steps are given in the OTM 1000 , OTR 1003 and OmniTek LAB user guides.)
1.
Set the OTR to generate output in the appropriate video standard as described in Section P.2.
2.
Load all the frames of the special A/V Delay Test Sequence that is applicable to the video
format that is under test (see ‘Test Sequences’ above).
For information on loading a sequence, see Section R.2.
3.
Call up the Properties of the Test Sequence and check that the
Resize type
for this pattern is
set to
None
. (See Section Q.5)
4.
Where the
TSA
(PCM-only) test sequence is being used
, set the
Audio Tone Generator
to
generate a tone on channel 1 set for 8kHz, -18dB (see Section Q.6) and set the associated
Click Mode
to
Mutes except on frame 1
.
These settings are essential for correct operation.
5.
Play the Test Sequence as a continuous loop.
Note:
Where the sequence is recorded to tape/disk, it is sensible to record at least a minute of the
repeating sequence to make operation and measurement easier.
Содержание OTR 1001
Страница 1: ...Advanced Measurement Technology OTR 1001 User Guide Software Version 3 1 October 2013...
Страница 28: ...OmniTek OTR 1001 User Guide v3 1a A 16...
Страница 52: ...OmniTek OTR 1001 User Guide v3 1 B 24...
Страница 96: ...OmniTek OTR 1001 User Guide v3 1a E 24...
Страница 116: ...OmniTek OTR 1001 User Guide v3 1 G 6...
Страница 124: ...OmniTek OTR 1001 User Guide v3 1 H 8...
Страница 130: ...OmniTek OTR 1001 User Guide v3 1 I 6 Figure I 3 Difference view Figure I 4 Anaglyph representation...
Страница 184: ...OmniTek OTR 1001 User Guide v3 1 J 22...
Страница 238: ...OmniTek OTR 1001 User Guide v3 1 M 14...
Страница 250: ...OmniTek OTR 1001 User Guide v3 1 N 12...
Страница 254: ...O 4 OmniTek OTR 1001 User Guide v3 1...
Страница 280: ...Q 14 OmniTek OTR 1001 User Guide v3 1 Figure Q 12 Video Index options within the Gen window Properties...
Страница 283: ...OmniTek OTR 1001 User Guide v3 1 Q 17 Figure Q 15 Save File settings within the Gen window Properties...
Страница 292: ...Q 26 OmniTek OTR 1001 User Guide v3 1...
Страница 326: ...OmniTek OTR 1001 User Guide v3 1a S 26...
Страница 358: ...OmniTek OTR1001 User Guide v3 1 U 12...
Страница 364: ...OmniTek OTR 1001 User Guide v3 1 V 6...
Страница 379: ...OmniTek OTR 1001 User Guide v3 1 I 15 Example XML Statements Example Result...
Страница 386: ...OmniTek OTR 1001 User Guide v3 1 II 6...
Страница 389: ...OmniTek OTR 1001 User Guide v3 1...