![OmniTek OTR 1001 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/omnitek/otr-1001/otr-1001_user-manual_739908084.webp)
OmniTek OTR 1001 User Guide, v3.1a
E-12
Configuration Issues
The following Configuration settings affect how the Vectorscope is displayed.
Note:
Further
settings are required where 3D images are analysed: these are described in Section I.8.
Error Mask
The OTR 1001 allows you to specify a number of lines from the top and bottom of the display
and a number of pixels from the left and right edge that can be omitted from the checking
process. This is referred to as an Error Mask and it is defined on the
Video Config
page of the
Config window. Its purpose is to avoid producing misleading results as a result of including
video data that has been corrupted by the sync.
Composite Matrix
Different matrices may be applied in producing the
composite version of the Vectorscope display. The OTR
can either be set to select the appropriate matrix
automatically, based on the input video standard or it can
be set to select a particular composite matrix. The selection
is made through the
Composite Matrix Type
option
offered on the
Video Config
page of the Config window.
Display Properties
Other aspects of the Vectorscope are determined by the
tile’s properties, a complete read-out of which is given in
the Properties control (Control Panel: press PROPS to
display). Shortcuts to the most-commonly required settings
are provided through the Button Bar (Control Panel: press
GENERAL or OTHER; Mouse/Keyboard: click on tile to
display).
Mode of Operation
The
Filter
control selects
how the incoming data is
sampled. The choice offered is between a
Flat
filter, a
Low
Pass
filter or
No Interpolation
. The Button Bar option
cycles round these three options. When Labels are shown
(see
Show Labels
below), the type of filtering that is being
applied is shown in the bottom right-hand corner of the
display. The Button Bar option switches between
Interpolation On (button highlighted) and Interpolation Off.
Interpolation is usually enabled but users should be aware
that it can occasionally produce out of range results. Where
these occur, you may prefer to turn the interpolator off.
Button Bar
Figure E-9:
Vectorscope
Properties.
Содержание OTR 1001
Страница 1: ...Advanced Measurement Technology OTR 1001 User Guide Software Version 3 1 October 2013...
Страница 28: ...OmniTek OTR 1001 User Guide v3 1a A 16...
Страница 52: ...OmniTek OTR 1001 User Guide v3 1 B 24...
Страница 96: ...OmniTek OTR 1001 User Guide v3 1a E 24...
Страница 116: ...OmniTek OTR 1001 User Guide v3 1 G 6...
Страница 124: ...OmniTek OTR 1001 User Guide v3 1 H 8...
Страница 130: ...OmniTek OTR 1001 User Guide v3 1 I 6 Figure I 3 Difference view Figure I 4 Anaglyph representation...
Страница 184: ...OmniTek OTR 1001 User Guide v3 1 J 22...
Страница 238: ...OmniTek OTR 1001 User Guide v3 1 M 14...
Страница 250: ...OmniTek OTR 1001 User Guide v3 1 N 12...
Страница 254: ...O 4 OmniTek OTR 1001 User Guide v3 1...
Страница 280: ...Q 14 OmniTek OTR 1001 User Guide v3 1 Figure Q 12 Video Index options within the Gen window Properties...
Страница 283: ...OmniTek OTR 1001 User Guide v3 1 Q 17 Figure Q 15 Save File settings within the Gen window Properties...
Страница 292: ...Q 26 OmniTek OTR 1001 User Guide v3 1...
Страница 326: ...OmniTek OTR 1001 User Guide v3 1a S 26...
Страница 358: ...OmniTek OTR1001 User Guide v3 1 U 12...
Страница 364: ...OmniTek OTR 1001 User Guide v3 1 V 6...
Страница 379: ...OmniTek OTR 1001 User Guide v3 1 I 15 Example XML Statements Example Result...
Страница 386: ...OmniTek OTR 1001 User Guide v3 1 II 6...
Страница 389: ...OmniTek OTR 1001 User Guide v3 1...