![OmniTek OTR 1001 Скачать руководство пользователя страница 234](http://html1.mh-extra.com/html/omnitek/otr-1001/otr-1001_user-manual_739908234.webp)
OmniTek OTR 1001 User Guide, v3.1
M-10
Vertical Gain and Vertical Offset
The
V Gain
and
V Offset
controls determine the vertical scaling and the positioning of the
display. (The
V Gain
option on the Button Bar cycles through the available scalings.)
Note:
The
V Gain
control is disabled in Auto Measure mode.
Cursors
The Cursor options control the cursor-pairs that can be used to measure time differences and
voltage differences between any two points on the Eye Diagram.
The
Show Cursors
option in the Properties control provides overall control of the display of any
cursors over the display, while the
Cursors
option on the Button Bar switches between these
cursors (and associated markers such as those marking the 20% and 80% level) being shown and
being hidden.
The
Time Cursors
and
Voltage Cursors
tick selections separately control the display of a pair
of cursors providing difference measurements in the horizontal (
time
) direction and the vertical
(
voltage
) direction. When the cursors are displayed, a read-out of the times and voltage
differences measured is shown in the top right-hand corner of the screen as
dx
and
dy
values.
Visualisation
The
Gain
control adjusts the intensity of the displayed signal (as a percentage of the received
signal level).
Note:
This control is disabled in Auto Measure mode.
The
Persistence
setting sets the rate at which the displayed data decays. Larger values have the
result of smoothing out time variations.
Note:
This control is disabled in Auto Measure mode.
The
Gamma
setting applies gamma encoding to the signal. A setting of 100 corresponds to a
gamma value of 1. Values below 100 emphasise differences in low-level signal strengths, while
values over 100 emphasise differences in high-level signal strengths.
The
Colour
setting selects the colour used for the waveform trace (out of
Cyan
,
Green
,
White
or ‘
Temperature Ramp
’). The
Colour
option in the Button Bar cycles through the available
colours.
The
CRT Emulation
option applies a special filter to the waveform data to emulate how the Eye
might be displayed on a CRT-based waveform monitors. Selecting the
CRT Emulation
option
on the Button Bar switches this option between On and Off.
Show Graticule
controls the display of the underlying Graticule.
The
Jitter Meter
option controls how the Jitter meter is displayed.
Equalisation
The
Equalised
tick box sets whether the signal is viewed after it has passed through an internal
cable equalizer that compensates for loss introduced by the cable. Ticking the
Equalised
option
is normally only worth doing where the signal is otherwise approximately jitter free. The Button
Bar option switches this setting between On and Off.
Note:
This control is disabled in Auto
Measure mode.
Eye Sample Rate
Sets the timebase for the pattern by selecting the number of eyes to be formed. The Button Bar
option cycles through the available settings.
Note:
This control is disabled in Auto Measure mode.
Auto Measure
Selects the OTR’s automatic measurement mode. The Button Bar option switches this setting
between On and Off.
Содержание OTR 1001
Страница 1: ...Advanced Measurement Technology OTR 1001 User Guide Software Version 3 1 October 2013...
Страница 28: ...OmniTek OTR 1001 User Guide v3 1a A 16...
Страница 52: ...OmniTek OTR 1001 User Guide v3 1 B 24...
Страница 96: ...OmniTek OTR 1001 User Guide v3 1a E 24...
Страница 116: ...OmniTek OTR 1001 User Guide v3 1 G 6...
Страница 124: ...OmniTek OTR 1001 User Guide v3 1 H 8...
Страница 130: ...OmniTek OTR 1001 User Guide v3 1 I 6 Figure I 3 Difference view Figure I 4 Anaglyph representation...
Страница 184: ...OmniTek OTR 1001 User Guide v3 1 J 22...
Страница 238: ...OmniTek OTR 1001 User Guide v3 1 M 14...
Страница 250: ...OmniTek OTR 1001 User Guide v3 1 N 12...
Страница 254: ...O 4 OmniTek OTR 1001 User Guide v3 1...
Страница 280: ...Q 14 OmniTek OTR 1001 User Guide v3 1 Figure Q 12 Video Index options within the Gen window Properties...
Страница 283: ...OmniTek OTR 1001 User Guide v3 1 Q 17 Figure Q 15 Save File settings within the Gen window Properties...
Страница 292: ...Q 26 OmniTek OTR 1001 User Guide v3 1...
Страница 326: ...OmniTek OTR 1001 User Guide v3 1a S 26...
Страница 358: ...OmniTek OTR1001 User Guide v3 1 U 12...
Страница 364: ...OmniTek OTR 1001 User Guide v3 1 V 6...
Страница 379: ...OmniTek OTR 1001 User Guide v3 1 I 15 Example XML Statements Example Result...
Страница 386: ...OmniTek OTR 1001 User Guide v3 1 II 6...
Страница 389: ...OmniTek OTR 1001 User Guide v3 1...