Third There are 3 different versions of product.
First
System controller Version
Second
Front panel Version
Third
SCPI protocol Version
Fourth
Channel 1 or 2 which is connected with interface.
ex) *idn?
return value "ODA Technologies,OPX-Series,1.3-1.3-1.2,2"
*SN?
*SN?
Able to check the serial number of power supply. This is appliable for Windows application.
Return value "oda-00-0000-00000"
ex) *SN?
return value "oda-01-0923-00185"
*SAV {1|2|3|4|5|6|7|8|10}
It is command which saves in『User memory』power supply voltage current protection level
It is command which saves in
User memory』power supply voltage, current, protection level.
There are number 1~10 memories.
> 1 ~ 10 Memory saving range
ex) *sav 2
Save in number 2 memory
*RCL {1|2|3|4|5|6|7|8|10}
It is command which applys saved 『User Memory』to power supply.
Memories are selectable from 1 to 10.
Memories are selectable from 1 to 10.
> 1 ~ 10 Memory range
ex) *rcl 2
Apply number 2 memory to power supply
*CLS
It is command which clears all error stack.
ex) *CLS
*RST
It is command about Power Supply reset. It is description below.
> Output
OFF
> Voltage Limit
0V
> Current Limit
set-up maximum value
> OVP
OVP set-up maximum value
> OCP
OCP set-up maximum value
> OCP
OCP set up maximum value
> UVL
0V
> OVL
Voltage Limit MAX value
> UCL
0A
> OCL
Current Limit MAX value
> Volt:Step
Set-up minimum value
> Curr:Step
Set-up minimum value
> Key Lock
OFF
> Factory Mode Maintains seting before Reset.
> Trip Condition Automatically clears when OVP or OCP is tripped.
ex) *RST
Initialize Power Supply.
- 67 -