5 4 LAST STATE
5-4. LAST STATE
▌When power is ON, this function restore setting before it was OFF.
▌Function
> DISABLE
Booting power supply with standard value.
We recommend Disable mode for safety.
> SAFETY
It restores setting before the product is OFF However it maintains basic
> SAFETY
It restores setting before the product is OFF. However, it maintains basic
output ON/OFF Therefore, it is safe because it will be booted Output OFF.
> FULLY
Restore previous value before it was OFF.
It restores Output setting also, can be dangerous because when it is booted,
it is starting with output ON.
LAST STATE Operation
▌Power Switch ON while pressing FACTORY Key.
▌Power Switch ON
Holding
▌
When
"
1. USER-MEM CLEAR
" is displayed, release FACTORY Key.
▌
Use cursor key to move on to
"
2. LAST STATE
" Menu.
▌To set-up, press FACTORY Key once more.
LCD Display Description
DISABLE
Release
LCD Display Description
DISABLE
▌
Use cursor key to move to "SAFETY" and check Safe Mode.
LCD Display Description
SAFETY
▌To apply, press FACTORY Key once more.
LCD Display Description
Done