3-9. Programming Over Current Limit(OCL)
It is possible to variety 0A to maximum current using encoder switch. However if user input
from this point, it can only variety 0A to OCL current set-up value.
OCL Level Value below can be different.
▌Power Switch ON
Check whether "**OUTPUT OFF**" is displayed after Power ON.
▌Before set-up OCL, current limit should be lower than OCL set-up value.
Therefore, set-up current first.
▌To set-up current, use right cursor key to change current range and rotate
encoder switch to set-up value.
Current cannot rise more than the Protection Level in Protection (OVP/UVL
will be displayed and current will be set-up protection level value
/OVL) If it tries to rise more than protection level, "PROTECTION LIMIT"
will be displayed and current will be set up protection level value.
▌Press PROTECT Key to set-up OCL Level.
LCD Display Description
PROTECT> 1.OVP
▌Use right cursor key to move on to OCL Menu.
LCD Display Description
PROTECT> 6.OCL
▌Press PROTECT Key once more in "PROTECT> 6.OCL" condition.
LCD Display Description
OCL SET> 3.1500A
▌Use cursor key to change the value.
▌Use encoder switch to change Level value.
OCL Level cannot be set-up lower than present setting value.
p
p
g
▌Press PROTECT Key when it is done.
LCD Display Description
Changed
Return to previous page when message above is displayed.
To cancel
▌To cancel, press I/O LOCAL Key or wait for 10 seconds.
Wait 10 sec
LCD Display Description
Cancel…
Read reference earliest UCL set-up "1-6. Check after Input Power" "Earliest Setting Value"
Note
- 28 -