Third There can be a trip when load source. When Battery charge & discharge occurs,
its level can be higher than setting value.
Below diagram shows how to prevent it with inserting diode with right current capacity.
< Diagram 3-2 >
Fourth If it is difficult to manage Tripping, There is a way to Turn OVP Function OFF in force.
To turn it OFF, go to Factory Mode, and "Disable" "5.OVP USE".
▌When OVP Trip occurs, "OVP TRIPPED" message will be displayed.
▌To Clear OVP Trip, firstly raise OVP Level.
To set-up Level, press PROTECT Key.
LCD Display Description
PROTECT> 1.OVP
▌Press PROTECT Key once more in "PROTECT> 1.OVP " condition.
LCD Display Description
OVP SET> 8.500V
▌Use cursor key to change the value.
▌Use Encoder switch to raise Level value.
▌When it is done, press PROTECT Key to save.
LCD Display Description
Changed
After message above is displayed go back to before the trip
After message above is displayed, go back to before the trip.