5 8 OCP USE
5-8. OCP USE
▌Activate/deactivate Over Current Protection.
▌Any load leads to high-capacity can make OVP Trip often. Therefore this function prevents
inconvenience using the product.
▌When it is disabled, power will not be shut-down, be careful!
▌Function
> DISABLE
OCP Disabled
> ENABLE
OCP Enabled
OCP USE Operation
▌Power Switch ON while pressing FACTORY Key.
Holding
▌Power Switch ON
▌
When
"
1. USER-MEM CLEAR
" Message is displayed, release FACTORY Key.
▌
Use cursor key to move on to
"
6 OCP USE
" Menu
Release
▌
Use cursor key to move on to 6. OCP USE
Menu.
▌To set-up, press FACTORY Key once.
LCD Display Description
▌
Use cursor key to move to "DISABLE", and check disable mode.
LCD Display Description
ENABLE
DISABLE
▌To apply, press FACTORY Key once more.
LCD Display Description
Done
- 51 -