NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 982 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
[9]
INBUFFULL
TDES/DES in Buffer Full Flag
0 = TDES/DES input buffer is not full. Software can feed the data into the
TDES/DES engine.
1 = TDES input buffer is full. Software cannot feed data to the TDES/DES
engine. Otherwise, the flag INBUFERR will be set to 1.
[8]
INBUFEMPTY
TDES/DES in Buffer Empty
0 = There are some data in input buffer waiting for the TDES/DES engine
to process.
1 = TDES/DES input buffer is empty. Software needs to feed data to the
TDES/DES engine. Otherwise, the TDES/DES engine will be pending to
wait for input data.
[7:1]
Reserved
Reserved.
[0]
BUSY
TDES/DES Engine Busy
0 = TDES/DES engine is idle or finished.
1 = TDES/DES engine is under processing.