NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 296 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
[3:0]
DBCLKSEL
De-bounce Sampling Cycle Selection
0000 = Sample interrupt input once per 1 clocks.
0001 = Sample interrupt input once per 2 clocks.
0010 = Sample interrupt input once per 4 clocks.
0011 = Sample interrupt input once per 8 clocks.
0100 = Sample interrupt input once per 16 clocks.
0101 = Sample interrupt input once per 32 clocks.
0110 = Sample interrupt input once per 64 clocks.
0111 = Sample interrupt input once per 128 clocks.
1000 = Sample interrupt input once per 256 clocks.
1001 = Sample interrupt input once per 2*256 clocks.
1010 = Sample interrupt input once per 4*256 clocks.
1011 = Sample interrupt input once per 8*256 clocks.
1100 = Sample interrupt input once per 16*256 clocks.
1101 = Sample interrupt input once per 32*256 clocks.
1110 = Sample interrupt input once per 64*256 clocks.
1111 = Sample interrupt input once per 128*256 clocks.