Note:
This bit will be cleared by hardware automatically.
[25]
CACT
Timer Is in Active
This bit indicates the counter status of timer.
0 = Timer is not active.
1 = Timer is in active.
[24:8]
Reserved
Reserved.
[7:0]
PRESCALE
Clock Pre-scale Divide Count
Clock input is divided by PR 1 before it is fed to the counter (here
PRESCALE is considered as a decimal number). If PRESCALE = 0, then there is no
scaling.