NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 1218 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
ADC Touch Z Pressure Data (ADC_ZDATA)
Register
Offset
R/W
Description
Reset Value
ADC_ZDATA
0x24
R
ADC Touch Z Pressure Data
0x0000_0000
Bits
Description
[31:28]
Reserved
Reserved.
[26:16]
ADC_Z2DATA
ADC Z2 Data
When Z_EN (ADC_CONF[1]) in ADC_FM register is set; the touch pressure measure Z2
will be stored in this register.
Note:
If the DISZMAVEN (ADC_CONF[21]) = 1, both Z1 and Z2 data is the results of the
mean average of Z1 and Z2 in ADC_ZSORT0 ~ ADC_ZSORT3.
[15:12]
Reserved
Reserved.
[11:0]
ADC_Z1DATA
ADC Z1 Data
When Z_EN (ADC_CONF[1]) in ADC_FM register is set; the touch pressure measure Z1
will be stored in this register.
Note:
If the DISZMAVEN (ADC_CONF[21])= 1, both Z1 and Z2 data is the results of the
mean average of Z1 and Z2 in ADC_ZSORT0 ~ ADC_ZSORT3.
31
30
29
28
27
26
25
24
Reserved
ADC_Z2DATA
23
22
21
20
19
18
17
16
ADC_Z2DATA
15
14
13
12
11
10
9
8
Reserved
ADC_Z1DATA
7
6
5
4
3
2
1
0
ADC_Z1DATA