![Nuvoton NUC970 series Скачать руководство пользователя страница 124](http://html1.mh-extra.com/html/nuvoton/nuc970-series/nuc970-series_technical-reference-manual_1720277124.webp)
NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 124 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
GPIOH Low Byte Multiple Function Control Register (SYS_GPH_MFPL)
Register
Offset
R/W
Description
Reset Value
SYS_GPH_MF
PL
0x0A8
R/W
GPIOH Low Byte Multiple Function Control Register
0x0000_0000
31
30
29
28
27
26
25
24
MFP_GPH7
MFP_GPH6
23
22
21
20
19
18
17
16
MFP_GPH5
MFP_GPH4
15
14
13
12
11
10
9
8
MFP_GPH3
MFP_GPH2
7
6
5
4
3
2
1
0
MFP_GPH1
MFP_GPH0
Bits
Description
[31:28]
MFP_GPH7
Pin PH.7 Multi Function Selection
0000 = PH.7.
0100 = KPI_ROW3.
0110 = SD1_CLK.
1001 = UR1_CTS.
1110 = EBI_ADDR3.
1111 = EINT7.
Others = PH.7.
[27:24]
MFP_GPH6
Pin PH.6 Multi Function Selection
0000 = PH.6.
0100 = KPI_ROW2.
0110 = SD1_CMD.
1001 = UR1_RTS.
1110 = EBI_ADDR2.
1111 = EINT6.
Others = PH.6.
[23:20]
MFP_GPH5
Pin PH.5 Multi Function Selection
0000 = PH.5.
0100 = KPI_ROW1.
1001 = UR1_RXD.
1110 = EBI_ADDR1.
1111 = EINT5.