NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 880 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
[14:10]
F2_ECNT
Error Count of ECC Field 2
This field contains the error counts after ECC correct calculation of Field 2. For this ECC core
(BCH algorithm), only when F2_STAT equals to 0x01, the value in this field is meaningful.
F2_ECNT means how many errors depending on which ECC is used.
[9:8]
F2_STAT
ECC Status of Field 2
This field contains the ECC correction status (BCH algorithm) of ECC-field 2.
00 = No error.
01 = Correctable error.
10 = Uncorrectable error.
11 = Reserved.
[7]
Reserved
Reserved.
[6:2]
F1_ECNT
Error Count of ECC Field 1
This field contains the error counts after ECC correct calculation of Field 1. For this ECC core
(BCH algorithm), only when F1_STAT equals to 0x01, the value in this field is meaningful.
F1_ECNT means how many errors depending on which ECC is used.
[1:0]
F1_STAT
ECC Status of Field 1
This field contains the ECC correction status (BCH algorithm) of ECC-field 1.
00 = No error.
01 = Correctable error.
10 = Uncorrectable error.
11 = Reserved.