NUC970 Technical Reference Manual
Publication Release Date: Dec. 15, 2015
- 902 -
Revision V1.30
NUC97
0
T
E
CHNIC
A
L
RE
F
E
RE
N
CE
MA
NUA
L
NAND Flash ECC Error Data Register 1 (FMI_NANDECCED1)
Register
Offset
R/W
Description
Reset Value
FMI_NANDECCED1
0x964
R
NAND Flash ECC Error Data Register 1
0x8080_8080
31
30
29
28
27
26
25
24
ERR_DATA7
23
22
21
20
19
18
17
16
ERR_DATA6
15
14
13
12
11
10
9
8
ERR_DATA5
7
6
5
4
3
2
1
0
ERR_DATA4
Bits
Description
[31:24]
ERR_DATA7
ECC Error Data of First Field 7
This field contains an 8-bit BCH ECC error data 7 of first field. If it is a correctable error, please
read out the error data in this field and doing bitwise XOR with received data locating at
address ERR_ADDR7 (FMI_NANDECCEA3[26:16]), and then the result will be the correct
data.
[23:16]
ERR_DATA6
ECC Error Data of First Field 6
This field contains an 8-bit BCH ECC error data 6 of first field. If it is a correctable error, please
read out the error data in this field and doing bitwise XOR with received data locating at
address ERR_ADDR6 (FMI_NANDECCEA3[10:0]), and then the result will be the correct data.
[15:8]
ERR_DATA5
ECC Error Data of First Field 5
This field contains an 8-bit BCH ECC error data 5 of first field. If it is a correctable error, please
read out the error data in this field and doing bitwise XOR with received data locating at
address ERR_ADDR5 (FMI_NANDECCEA2[26:16]), and then the result will be the correct
data.
[7:0]
ERR_DATA4
ECC Error Data of First Field 4
This field contains an 8-bit BCH ECC error data 4 of first field. If it is a correctable error, please
read out the error data in this field and doing bitwise XOR with received data locating at
address ERR_ADDR4 (FMI_NANDECCEA2[10:0]), and then the result will be the correct data.