Commander S100 User Guide
11
2.7 Motor sizing
The motor rated current generally should not exceed the maximum continuous output current of the drive as listed in Table 2-1 to Table 2-3.
The maximum output voltage of the drive is not able to exceed the input voltage, except for 100 V drive which use a voltage doubler to give 200 V
output. The rated voltage of the motor should be similar to the output voltage of the drive. Motors can often be configured for different voltage ranges
e.g. (star wye) or delta configuration of the windings. Ensure the configuration matches the drive and supply voltages.
The drive will initiate an error if the drive output current exceeds the over-current threshold, which could occur in the event of a short circuit of the
motor output cables. The over-current threshold is the maximum current the drive can measure.
2.8 Drive features
Figure 2-3 Features of the drive
2.8.1 Items supplied with the drive
Table 2-4 Items supplied with the drive
Table 2-5 Accessories
1
3
7
8
10
12
13
6
9
11
5
4
2
13
14
14
15
Key
1. DIN Rail Release
2. NFC Reader Location
3. Keypad
4. Display
5. Rating information (side of drive)*
6. Model number
7. Relay connections
8. Digital IO Connections
9. 485 communication Port
10. Analog I/O connections
11. EMC filter disconnect Screw **
12. A.C. supply and motor connections
13. Cable management bracket attachment points / alternative ground
connections (2 x size M3 screws not provided)
14. Ground (protective earth) connections (2 x M4 screws provided)
15. EMC backplate screw
*Always check the drive voltage rating is suitable for the installation
**Read information in section 4
before removal.
Description
Further Details
2 x 8 mm M4 (Phillips/Slotted)
These screws should be used to attach the ground cable as covered in section 4.1.3
Name
Control Techniques
Part Number
Further Details
Remote
IP 66 Keypad
82500000000001
Remote LED keypad rated at IP66.
Cable Management
Bracket
3470-0207
Bracket that can be used to ground cable screens and allow for improved cable
management. Supplied with two 6 mm M3 (Phillips/Slotted) screws for
installation.
CT Comms Cable
4500-0096
Connects to the drive 485 port to allow communication to the PC. This is required
for use with software such as Connect and CT Scope.
Содержание COMMANDER S100
Страница 118: ...0478 0650 02...