Commander S100 User Guide
109
10.1.2 Altitude
Altitude range of the Commander S100 is 0 to 3,000 m (9,900 ft), subject to the following conditions:
•
0 m to 1000 m above sea level: no derate required.
•
1,000 m to 3,000 m (3,300 ft to 9,900 ft) above sea level: de-rate the maximum output current from the specified figure by 1 % per 100 m (330 ft)
above 1,000 m (3,300 ft). For example at 3,000 m (9,900 ft) the output current of the drive would have to be de-rated by 20 %.
200 V Drive (200 to 240 V ±10 %)
S100-01S13
0.18
0.25
1.4
1.2
1.2
1.2
1
1
S100-01213
0.18
0.25
1.4
1.2
1.2
1.2
1
1
S100-02S11
0.18
0.25
1.2
1
1
1
0.8
0.8
S100-01S23
0.25
0.33
1.6
1.4
1.4
1.4
1.2
1.2
S100-01223
0.25
0.33
1.6
1.4
1.4
1.4
1.2
1.2
S100-02S21
0.25
0.33
1.4
1.2
1.2
1.2
1
1
S100-01S33
0.37
0.5
2.4
1.6
1.6
1.6
1.4
1.4
S100-01233
0.37
0.5
2.4
1.6
1.6
1.6
1.4
1.4
S100-02S31
0.37
0.5
2.2
1.4
1.4
1.4
1.2
1.2
S100-01S43
0.55
0.75
3.5
2.4
2.4
2.4
1.6
1.6
S100-01243
0.55
0.75
3.5
2.4
2.4
2.4
1.6
1.6
S100-02S41
0.55
0.75
3.2
2.2
2.2
2.2
1.4
1.4
S100-01S53
0.75
1
4.6
3.5
3.5
3.5
2.4
2.4
S100-01253
0.75
1
4.6
3.5
3.5
3.5
2.4
2.4
S100-02S51
0.75
1
4.2
3.2
3.2
3.2
2.2
2.2
S100-01D63
1.1
1.5
6.6
4.6
4.6
4
3.5
3.5
S100-02S61
1.1
1.5
6
3.6
4.2
3.4
3.2
2.8
S100-01D73
1.5
2
7.5
6.6
6.6
5.5
4.6
4.6
S100-02S71
1.5
2
6.8
6
6
5.5
4.2
4.2
S100-03D13
2.2
3
10.6
6.8
7.5
6.6
6.6
5.5
400 V Drive (380 to 480 V ±10 %)
S100-02413
0.37
0.5
1.2
1
0.8
S100-02423
0.55
0.75
1.7
0.5
1.2
1
S100-02433
0.75
1
2.2
0.6
1.7
1.2
S100-02443
1.1
1.5
3.2
0.8
2.2
0.5
1.7
S100-02453
1.5
2
3.7
1
3.2
0.55
2.2
S100-02463
2.2
3
5.3
1.2
3.7
0.55
3.2
S100-03413
3
3
7.2
2.2
5.3
1.2
3.7
0.8
S100-03423
4
5
8.8
3.2
7.2
1.2
5.3
1
Drive Model Number
Nominal Power
Rating
Maximum continuous
output current @ 40
o
C
Maximum continuous
output current @ 50
o
C
Maximum continuous
output current @ 60 °C
kW
hp
4 kHz
12 kHz
4 kHz
12 kHz
4 kHz
12 kHz
A
A
A
A
A
A
Содержание COMMANDER S100