If the system-level diagnostics
tests…
Then…
Were completed without any
failures
a. Clear the status logs:
sldiag device clearstatus
b. Verify that the log was cleared:
sldiag device status
The following default response is displayed:
SLDIAG: No log messages are present.
c. Exit Maintenance mode:
halt
The node displays the LOADER prompt.
d. Boot the node from the LOADER prompt:
bye
e. Return the node to normal operation:
If your node is in…
Then…
An HA pair
Perform a give back:
storage failover giveback -ofnode
replacement_node_name
If you disabled automatic giveback, re-enable it with the
storage failover modify command.
747