dns_addr is the IP address of a name server on your network.
▪
dns_domain is the Domain Name System (DNS) domain name.
If you use this optional parameter, you do not need a fully qualified domain name in the netboot
server URL. You need only the server’s host name.
Other parameters might be necessary for your interface. You can enter
help
ifconfig
at the firmware prompt for details.
8. If the controller is in a stretch or fabric-attached MetroCluster, you must restore the FC adapter
configuration:
a. Boot to Maintenance mode:
boot_ontap maint
b. Set the MetroCluster ports as initiators:
ucadmin modify -m fc -t
initiator
adapter_name
c. Halt to return to Maintenance mode:
halt
The changes will be implemented when the system is booted.
Boot the recovery image - FAS8200
The procedure for booting the impaired controller from the recovery image depends on
whether the system is in a two-node MetroCluster configuration.
Option 1: Most systems
:
You must boot the ONTAP image from the USB drive, restore the file system, and verify the environmental
variables.
This procedure applies to systems that are not in a two-node MetroCluster configuration.
Steps
1. From the LOADER prompt, boot the recovery image from the USB flash drive:
boot_recovery
The image is downloaded from the USB flash drive.
2. When prompted, either enter the name of the image or accept the default image displayed inside the
brackets on your screen.
3. Restore the var file system: