cluster_B::> metrocluster show
Cluster Configuration State Mode
-------------------- ------------------- ---------
Local: cluster_B configured normal
Remote: cluster_A configured normal
If a switchback is taking a long time to finish, you can check on the status of in-progress baselines by using
the
metrocluster config-replication resync-status show
command.
6. Reestablish any SnapMirror or SnapVault configurations.
Step 4: Complete the replacement process
Return the failed part to NetApp, as described in the RMA instructions shipped with the kit. See the
Controller
Overview of controller module replacement - FAS8300 and FAS8700
You must review the prerequisites for the replacement procedure and select the correct
one for your version of the ONTAP operating system.
• All drive shelves must be working properly.
• If your system is in a MetroCluster configuration, you must review the section
to determine whether you should use this procedure.
If this is the procedure you should use, note that the controller replacement procedure for a controller in a
four or eight node MetroCluster configuration is the same as that in an HA pair. No MetroCluster-specific
steps are required because the failure is restricted to an HA pair and storage failover commands can be
used to provide nondisruptive operation during the replacement.
• You must replace the failed component with a replacement FRU component you received from your
provider.
• You must be replacing a controller module with a controller module of the same model type. You cannot
upgrade your system by just replacing the controller module.
• You cannot change any drives or drive shelves as part of this procedure.
• In this procedure, the boot device is moved from the impaired controller to the
replacement
controller so
that the
replacement
controller will boot up in the same version of ONTAP as the old controller module.
• It is important that you apply the commands in these steps on the correct systems:
◦
The
impaired
controller is the controller that is being replaced.
◦
The
replacement node
is the new controller that is replacing the impaired controller.
◦
The
healthy
controller is the surviving controller.
• You must always capture the controller’s console output to a text file.
This provides you a record of the procedure so that you can troubleshoot any issues that you might
encounter during the replacement process.