If you need to or want to cold-swap the FlashCache module, follow the procedures for replacing
an I/O module.
Before you begin
Your storage system must meet certain criteria depending on your situation:
• It must have the appropriate operating system for the caching module you are installing.
• The caching module must be functioning well enough to be seen by the system. If the caching module is
not functioning since the last boot, you cannot use this procedure and must use the cold-swap procedure.
• It must support the caching capacity.
• The replacement caching module must have the same capacity as the failed caching module, but can be
from a different supported vendor.
• All other components in the storage system must be functioning properly; if not, you must contact technical
support.
Steps
1. If you are not already grounded, properly ground yourself.
2. Locate the failed caching module, in slot 6, by the lit amber Attention LED on the front of the caching
module.
3. Prepare the caching module slot for replacement as follows:
a. Record the caching module capacity, part number, and serial number on the target node:
system
node run local sysconfig -av 6
b. In admin privilege level, prepare the target NVMe slot for removal, responding
y
when prompted
whether to continue:
system controller slot module remove -node node_name -slot
slot_number
The following command prepares slot 6-1 on node1 for removal, and displays a
message that it is safe to remove:
::> system controller slot module remove -node node1 -slot 6-1
Warning: SSD module in slot 6-1 of the node node1 will be powered off
for removal.
Do you want to continue? (y|n): `y`
The module has been successfully removed from service and powered
off. It can now be safely removed.
c. Display the slot status with the
system controller slot module show
command.
The NVMe slot status displays
powered-off
in the screen output for the caching module that needs
replacing.
See the
for your version of ONTAP for more details.
4. Remove the caching module:
721