CHAPTER 13: TROUBLESHOOTING
LMV1000 (G)(E) AIR-COOLED LASER MARKER
990-541
13-3
Error
Code
Problem LD
1
Cause/Corrective
Action
42
RF Power Reflective waveform
excessive
OFF
The measured back RF reflection is excessive. The possible
causes for this error are:
Poor RF cable connection, check cable connection.
Faulty RF Power Unit
Faulty Q-Switch
Recycle the power on the Marker. If this error persists, contact
Miyachi America.
50
RF Temperature Error
OFF
The RF Unit is overheating. The possible causes for this error
are:
Dirty Control Unit Air-filter, clean as necessary.
High Ambient temperature,
t
95
q
F (~35
q
C)
Perform corrective action, and then wait at least 10 minutes
before re-starting the Marker. If this error persists, contact
Miyachi America.
51
LD Temperature Error
OFF
The LD (Laser Diode) Module is overheating. The possible
causes for this error are:
Dirty Control Unit Air-filter, clean as necessary.
Faulty Peltier Cooling Unit
High Ambient temperature,
t
95
q
F (~35
q
C)
Perform corrective action, and then wait at least 10 minutes
before re-starting the Marker. If this error persists, contact
Miyachi America.
52
Crystal Temperature Error
OFF
The Nd:YVO
4
Crystal is overheating. The possible causes for
this error are:
Dirty Control Unit Air-filter, clean as necessary.
Faulty Peltier Cooling Unit
High Ambient temperature,
t
95
q
F (~35
q
C)
Perform corrective action, and then wait at least 10 minutes
before re-starting the Marker. If this error persists, contact
Miyachi America.
60–75
Control Unit error
—
Control Unit errors.
Recycle Power. If the error reoccurs, contact the Miyachi
America Corporation.
1.
This column shows the condition of the LD (Laser Diode) Module when the error is detected. A “—“ indicates no
change.
Содержание LMV1000
Страница 8: ...LMV1000 G E AIR COOLED LASER MARKER viii 990 541...
Страница 9: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 ix...
Страница 17: ......
Страница 35: ......
Страница 47: ......
Страница 215: ...8 COMMUNICATION FUNCTION OPTION LMV1000 G E AIR COOLED LASER MARKER 8 14 990 541...
Страница 231: ......
Страница 237: ......
Страница 238: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 11 1 CHAPTER 11 OUTLINE DIMENSIONS 1 Dimensions Control Unit Oscillator...
Страница 239: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 2 990 541 Oscillator Continued...
Страница 241: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 4 990 541 Oscillator 1 2 3 4...
Страница 243: ......
Страница 259: ......