LMV1000 (G)(E) AIR-COOLED LASER MARKER
990-541
4-1
CHAPTER 4
Installation and Connection
(1) Installation Location
When planning for the installation of the Marker, assure that the following conditions are met:
x
The Marker should be placed in a dedicated laser operation area. The person responsible for the
area (the Laser Safety Officer) must isolate the laser operation area from other work areas and
display signs warning that the laser operation area is off limits to unauthorized personnel.
x
See
Appendix A: Technical Specifications
for specific weight and dimensional requirements.
x
Use proper tools (wire strippers, pressure wire connectors, etc.) for termination of the
connecting cables.
x
The Marker should be placed on a firm, level surface that is free from vibration. Install the
Oscillator and workpiece on the same stand, to prevent marking distortion due to vibration.
x
Do
not
operate the unit where there is considerable dirt, dust, oil mist, chemicals, fumes,
moisture, or near a high-frequency noise source.
x
The ambient temperature should be between 41°F and 95°F (5°C - 35°C) and the relative
humidity 20% to 90%, non-condensing.
x
The area should have no rapid temperature fluctuations, which may cause dew condensation on
the optical surfaces.
x
To accommodate the standard cable lengths, the Control Unit, Oscillator and Computer must be
located within 9.8 feet (3m) of each other. Longer cables are available through special order.
x
If the outside of the Marker is stained, wipe it with a dry or slightly moistened cloth. If it is
badly stained, use neutral detergent or alcohol to clean it. Do
not
use paint thinner, acetone,
benzene, etc. which can discolor or deform the parts.
x
Allow adequate clearance on all sides of the Marker to allow for cooling, maintenance and
servicing. Use the
minimum
distances shown below:
Oscillator
Control Unit
Содержание LMV1000
Страница 8: ...LMV1000 G E AIR COOLED LASER MARKER viii 990 541...
Страница 9: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 ix...
Страница 17: ......
Страница 35: ......
Страница 47: ......
Страница 215: ...8 COMMUNICATION FUNCTION OPTION LMV1000 G E AIR COOLED LASER MARKER 8 14 990 541...
Страница 231: ......
Страница 237: ......
Страница 238: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 11 1 CHAPTER 11 OUTLINE DIMENSIONS 1 Dimensions Control Unit Oscillator...
Страница 239: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 2 990 541 Oscillator Continued...
Страница 241: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 4 990 541 Oscillator 1 2 3 4...
Страница 243: ......
Страница 259: ......