7: OPERATION WITH A PC
LMV1000 (G)(E) AIR-COOLED LASER MARKER
7-94
990-541
d.
Element data creation example
i.
Basic operation
Register the Data Matrix elements [
L shape
], [
Module
] and [
Quiet zone
] as individual
graphic data points in advance. Then generate the
Data Matrix
graphic code automatically
based on the encoding result (2-dimentional alignment information).
NOTE:
[
Quiet zone
] is required only when [
Reverse ON
] is selected. Specifying the [
L
shape
] is optional.
ii.
Elements of Data Matrix
[
L shape
], [
Module
] and [
Quiet zone
] are created with a command using the graphic
creation program.
iii.
Description on commands
J
(jump) command J=X,Y
Jumps (without drawing a line) from the current position to a designated position (X, Y).
The next command is executed with respect to the latter point (reference point).
The current graphic data position is preset at point (0, 0). If multiple graphic data files are
marked, then the mark will begin from the last coordinate position marked.
L
(line) command L=X,Y
Draws a line from the current position to a designated position (X, Y).
S
(intersection removal start point) command S=X,Y
Same as (b) except that the intersection start point is removed
E
(intersection removed end point) command E=X,Y
Same as (b) except that the intersection end point is removed.
R
(arc) command R=X,Y,I,J,D
Draws an arc from the current point to a designated point (X, Y) around center position (I,
J). The direction (D) is clockwise when D = 0, or counterclockwise when D = 1. If the
current positions are specified, a circle is drawn. If there is a distance difference in center
positions between the current position and designated position, the start point will not be
continuous because the arc radius is calculated from center position (I, J) and designated
position (X, Y).
Laser parameter commands, etc.
Laser parameters, shutter timing, etc. are specified.
Содержание LMV1000
Страница 8: ...LMV1000 G E AIR COOLED LASER MARKER viii 990 541...
Страница 9: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 ix...
Страница 17: ......
Страница 35: ......
Страница 47: ......
Страница 215: ...8 COMMUNICATION FUNCTION OPTION LMV1000 G E AIR COOLED LASER MARKER 8 14 990 541...
Страница 231: ......
Страница 237: ......
Страница 238: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 11 1 CHAPTER 11 OUTLINE DIMENSIONS 1 Dimensions Control Unit Oscillator...
Страница 239: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 2 990 541 Oscillator Continued...
Страница 241: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 4 990 541 Oscillator 1 2 3 4...
Страница 243: ......
Страница 259: ......