LMV1000 (G)(E) AIR-COOLED LASER MARKER
990-541
13-1
CHAPTER 13
Troubleshooting
If the Marker experiences trouble, the Trouble light on the front panel will light and the error will
display on the
MarkMonitor
window. Perform corrective action according to the table below. Once the
source of trouble is fixed, press the
Reset
button in the
MarkMonitor
window to clear the error.
Error
Code
Problem LD
1
Cause/Corrective
Action
01
First standard character not
registered
—
First standard character data is not registered. Register first
standard character data.
02
Second standard character not
registered
—
Second standard character data is not registered. Register
second standard character data.
03
Figure not registered
—
Graphic data is not registered. Register graphic data.
04
Serial number not registered
—
Serial data is not registered. Register serial data.
05
Shared variable data not
registered
—
If this error occurs, contact Miyachi America Corporation.
06
Variable data not registered
—
Variable data is not registered. Register variable data.
07
Layout data not registered
—
Layout data is not registered. Register layout data.
08
The number of loops exceeds 100
—
If this error occurs, contact Miyachi America Corporation.
09
Marking speed error
—
Marking speed is set incorrectly. Set the marking speed to
an acceptable value.
10
ACK time over
—
No ACK received within the specified time. Investigate the
transfer device.
11
Layout command error
—
Layout error. Restart the control unit and PC, then transfer
the layout data.
12
Layout parameter error
—
There is an incorrect/unrecognized value in the layout data.
Check layout parameters and resend command.
13
Layout command insufficient
error
—
There is missing data in the layout command. Check layout
parameters and resend command.
14
Serial data overflow
—
Serial data has reached the maximum value. Check the
contents, and then reset the present value of the serial data.
15
Character command error
—
Character data error. Restart the control unit and PC, then
transfer the character data.
16
Marking area error
—
Layout error. Restart the control unit and PC, then transfer
the layout data.
20
Battery Voltage Low.
--
The Control Unit battery voltage is low. Replace battery.
Содержание LMV1000
Страница 8: ...LMV1000 G E AIR COOLED LASER MARKER viii 990 541...
Страница 9: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 ix...
Страница 17: ......
Страница 35: ......
Страница 47: ......
Страница 215: ...8 COMMUNICATION FUNCTION OPTION LMV1000 G E AIR COOLED LASER MARKER 8 14 990 541...
Страница 231: ......
Страница 237: ......
Страница 238: ...LMV1000 G E AIR COOLED LASER MARKER 990 541 11 1 CHAPTER 11 OUTLINE DIMENSIONS 1 Dimensions Control Unit Oscillator...
Страница 239: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 2 990 541 Oscillator Continued...
Страница 241: ...11 OUTLINE DIMENSIONS LMV1000 G E AIR COOLED LASER MARKER 11 4 990 541 Oscillator 1 2 3 4...
Страница 243: ......
Страница 259: ......