3 - 19
MELSEC-A
3 SPECIFICATIONS AND FUNCTIONS
3.5.3 List of input/output signal details
The details of each AD75 external device connection connector (for 1 axis) signal are
shown below.
Signal name
Pin No.
Signal details
Common
36
35
•
Common for near-point dog signal, upper/lower limit, stop signal,
speed/position changeover signal, and external start signal.
Manual pulse generator
(B phase –)
Manual pulse generator
(A phase –)
28
27
Manual pulse generator
(B phase +)
Manual pulse generator
(A phase +)
10
9
•
Input the pulse signal from the manual pulse generator A phase and B
phase.
•
If the A phase is advanced more than the B phase, the positioning
address will increase at the rising edge and falling edge of each phase.
•
If the B phase is advanced more than the A phase, the positioning
address will decrease at the rising edge and falling edge of each phase.
[When increased] [When decreased]
+1+1+1+1+1+1+1+1
-1 -1 -1 -1 -1 -1 -1 -1
A phase
B phase
Positioning
address
A phase
B phase
Positioning
address
Common 26
•
Common for drive unit READY and in-position.
Deviation counter clear common
23
•
Common for deviation counter clear.
Zero point signal common
25
•
Common for zero point signal (+5V) and zero point signal (+24V).
Zero point signal (+5V)
Zero point signal (+24V)
24
6
•
Input the zero point signal for machine zero point return.
Use the zero point signal of the pulse encoder or the like.
•
Use this signal when the zero point return method is the stopper method
and the machine zero point return complete is input from an external
source.
•
The zero point signal is detected at turning from OFF to ON.
Pulse sign
Pulse output (differential driver –)
22
21
Pulse sign
Pulse output (differential )
4
3
•
Output the positioning pulses and pulse sign for the differential driver
compatible drive unit.
Pulse sign common
Pulse output common
(Open collector)
20
19
Pulse sign
Pulse output (Open collector)
2
1
•
Output the positioning pulses and pulse sign for the open collector
compatible drive unit.
External start signal
16
•
Use as the positioning start, speed change request and skip request
input signal from an external source.
•
Set which function to use the external start signal with in " Pr.43
External start function selection".
Speed/position changeover signal
15
•
Input the control changeover signal for the speed/position changeover
control.
Stop signal
14
•
Input when positioning is stopped.
•
When this signal turns ON, the AD75 will stop the positioning being
executed.
After that, even if this signal turns from ON for OFF, the system will not
start.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание A1SD75P1-S3
Страница 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 16: ...A 13 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...A 20 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 25: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 275: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 617: ...Index 12 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...