6 - 26
MELSEC-A
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
(2)
Time chart for starting "high-speed zero point return"
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
9002
OFF
OFF
V
t
ON
OFF
Positioning start signal
PLC READY signal
AD75 READY signal
Start complete signal
BUSY signal
Error detection signal
Zero point absolute position overflow flag
[ Md.40 Status:b11]
Zero point absolute position under flow flag
[ Md.40 Status:b12]
Cd.11 Positioning start No.
[Y10]
[Y1D]
[X0]
[X1]
[X4]
[XA]
Fig. 6.5 Time chart for starting "high-speed zero point return"
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание A1SD75P1-S3
Страница 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 16: ...A 13 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...A 20 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 25: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 275: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 617: ...Index 12 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...