5 - 120
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Setting item
Setting details
Cd.27 Step mode
•
When using step operation, set which unit to step with.
Cd.28 Step start information
•
When using step operation, set whether to continue or restart operation.
Cd.29 Skip command
•
Set "1" to skip the current positioning.
Cd.30 New torque value
•
To change the "
Md.45 Torque limit stored value", set the new estimated torque
limit stored value.
•
Set the value within the "
Pr.18 Torque limit setting value" range.
Cd.31 Positioning starting point No.
•
Set the "start point No. (1 to 50)" for executing block start (positioning).
(If setting the value other than 1 to 50, process it as "1".)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание A1SD75P1-S3
Страница 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 16: ...A 13 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...A 20 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 25: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 275: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 617: ...Index 12 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...