5 - 47
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
4 : Count method 1)
(1) Start machine zero point return.
(Start movement at the " Pr.48 Zero point return speed" in
the " Pr.46 Zero point return direction".)
(2) Detect the near-point dog ON, and start deceleration.
(3) Decelerate to " Pr.49 Creep speed", and move with the
creep speed.
(4) After the near-point dog turns ON and the movement
amount set in " Pr.52 Setting for the movement amount
after near-point dog ON" has passed, the pulse output from
the AD75 stops with the first zero point signal (single-pulse
output per motor revolution), and the machine zero point
return is completed.
t
V
ON
(4)
(3)
(2)
(1)
Near-point dog OFF
Zero point signal
Zero point
return speed
Pr.48
Pr.49 Creep speed
Pr.52
Setting for the movement
amount after near-poing dog ON
First zero point after moving the
movement amount after near-
point dog ON
Movement amount after
near-point dog ON
Md.44
The near-point dog must turn OFF
at a sufficient distance away from
the zero point position.
5 : Count method 2)
(1) Start machine zero point return.
(Start movement at the " Pr.48 Zero point return speed" in
the " Pr.46 Zero point return direction".)
(2) Detect the near-point dog ON, and start deceleration.
(3) Decelerate to " Pr.49 Creep speed", and move with the
creep speed.
(4) After the near-point dog turns ON and the movement
amount set in " Pr.52 Setting for the movement amount
after near-point dog ON" has passed, the pulse output from
the AD75 stops, and the machine zero point return is
completed.
t
V
ON
(1)
(2)
(3)
(4)
Near-point dog OFF
Movement amount after
near-point dog ON
Md.44
Zero point
return speed
Pr.48
Pr.49 Creep speed
Pr.52
Setting for the movement
amount after near-poing dog ON
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание A1SD75P1-S3
Страница 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 16: ...A 13 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...A 20 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 25: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 275: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 617: ...Index 12 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...