6 - 6
MELSEC-A
6 SEQUENCE PROGRAM USED FOR POSITIONINGCONTROL
Device
Device
name
Axis 1 Axis 2 Axis 3
Application
Details when ON
M26
Parameter initialization command pulse
Parameter initialization commanded
M27
Parameter initialization command storage Parameter initialization command held
M28
Flash ROM write command pulse
Flash ROM write commanded
M29
Flash ROM write command storage
Flash ROM write command held
M30
Error code read complete
Error code read completed
M31
Error reset
Error reset completed
M32
–
Stop command pulse
Stop commanded
M9028
Clock data read command
Requesting clock data read
M9036
Always ON contact
Always ON contact
M9038
1 scan ON after RUN
1 scan turned ON after RUN
Internal
relay
M9039
1 scan OFF after RUN
1 scan turned OFF after RUN
D0 Status
information
( Md.40 Status)
D1
Zero point return request flag
( Md.40 Status (bit3))
D2
–
Zero point return request OFF results
( Cd.24 Zero point return request flag
OFF request)
D3 Date/hour
data
D4 Minute/second
data
PLC CPU clock data
D5
Clock data write request
( Cd.3
Clock data writing)
D6
Clock data write results
( Cd.3
Clock data writing)
D7
Positioning data No.
Positioning data No.
D8
Movement amount (low-order 16 bits)
D9
Movement amount (high-order 16 bits)
( Cd.21 Speed/position changeover
control movement amount
change register)
D10
JOG operation speed (low-order 16 bits)
D11
JOG operation speed (high-order 16 bits)
( Cd.19 JOG speed)
D12
Manual pulse generator 1 pulse input
magnification (low-order)
D13
Manual pulse generator 1 pulse input
magnification (high-order)
( Cd.23
Manual pulse generator 1
pulse input magnification)
D14
Speed change value (low-order 16 bits)
D15
Speed change value (high-order 16 bits)
( Cd.16 New speed value)
D16
Speed change request
( Cd.17 Speed change request)
D17
Speed change result
( Cd.17 Speed change request)
D18 Override
value
( Cd.18 Positioning operation speed
override)
D19
Acceleration time setting (low-order 16
bits)
D20
Acceleration time setting (high-order 16
bits)
( Cd.33 New acceleration time value)
D21
Deceleration time setting (low-order 16
bits)
D22
Deceleration time setting (high-order 16
bits)
( Cd.34 New deceleration time value)
D23
Torque limit value
( Md.45 Torque Limit stored value)
D24
Step valid flag
( Cd.26 Step valid flag)
D25 Step
mode
( Cd.27 Step mode)
D26
–
Skip operation results
( Cd.29 Skip command)
D27 Target
axis
( Cd.4
Target axis)
D28
Positioning data No.
( Cd.5
Positioning data No.)
Data
register
D29 Write
pattern
( Cd.6
Write pattern)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание A1SD75P1-S3
Страница 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 16: ...A 13 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...A 20 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 25: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 275: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...