5 - 75
MELSEC-A
5 DATA USED FOR POSITIONING CONTROL
Da.13 Parameter
Set the value as required for " Da.12 Special start command".
Da.12 Special start command
Setting value
Setting details
Block start (Normal start)
–
Not used. (There is no need to set.)
Condition start
Wait start
Simultaneous start
1 to 10
Set the condition data No. (No. of
"condition data" set to perform
condition judgment)
(For details of the condition data, refer
to Section 5.5.)
Stop
–
Not used. (There is no need to set.)
Repeated start (FOR loop)
0 to 255
Set the No. of repetitions.
Repeated start (FOR condition)
1 to 10
Set the condition data No. (No. of
"condition data" set to perform
condition judgment)
(For details of the condition data, refer
to Section 5.5.)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание A1SD75P1-S3
Страница 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 16: ...A 13 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...A 20 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 25: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 275: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 617: ...Index 12 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...