3 - 13
MELSEC-A
3 SPECIFICATIONS AND FUNCTIONS
3.4.2 Details of input signals (AD75 PLC CPU)
The ON/OFF timing and conditions, etc., of the input signals are shown below.
Device
No.
Signal name
Details
X0
AD75 READY
OFF : READY
complete
ON : Not
ready/WDT
error *3
•
When the PLC READY signal [Y1D] turns from OFF to ON, the parameter setting
range is checked, and if there is no error, this signal turns OFF.
•
When the PLC READY signal [Y1D] turns OFF, this signal turns ON.
•
When a WDT error occurs, this signal turns ON.
•
This is used for the interlock with the sequence program, etc.
OFF
ON
ON
OFF
PLC READY signal
[Y1D]
AD75 READY signal
[X0]
X1
X2
X3
Axis 1
Axis 2
Axis 3
Start
complete
OFF : Starting
incomplete
ON : Start
complete
•
When the positioning start signal turns ON, and the AD75 starts the positioning
process, this signal turns ON.
(The start complete signal also turns ON during zero point return control.)
OFF
ON
OFF
ON
Positioning start signal
[Y10]
Start complete signal
[X1]
X4
X5
X6
Axis 1
Axis 2
Axis 3
BUSY
*1
OFF : Not BUSY
ON : BUSY
•
This signal turns ON at the start of positioning, zero point return or JOG, and turns
OFF after the "
Da.8
Dwell time" has passed after positioning stop. (This signal
remains ON during positioning.) This signal turns OFF when stopped with step
operation.
•
During manual pulse generator operation, this signal turns ON while the "
Cd.22
Manual pulse generator enable flag" is ON.
•
This signal turns OFF at an error complete or stop.
X7
X8
X9
Axis 1
Axis 2
Axis 3
Positioning
complete
*2
OFF : Positioning
incomplete
ON : Positioning
complete
•
This signal turns ON for the time set in "
Pr.41
Positioning complete signal output
time" from the time that each positioning data No. positioning control is completed.
(This does not turn ON when "
Pr.41
Positioning complete signal output time" is 0.)
•
If positioning is started (including zero point return), JOG operation or manual pulse
generator operation start is executed while this signal is ON, the signal will turn OFF.
•
This signal will not turn ON when speed control or positioning is canceled midway.
•
After the BUSY signal [X4,X5,X6] turns OFF, the positioning complete signal
[X7,X8,X9] turns ON.
OFF
ON
ON
OFF
BUSY Signal [X4,X5,X6]
Positioning complete Signal [X7,X8,X9]
XA
XB
XC
Axis 1
Axis 2
Axis 3
Error
detection
OFF : No error
ON : Error
occurrence
•
This signal turns ON when an error listed in section 14.1 occurs, and turns OFF
when the error is reset.
XD
XE
XF
Axis 1
Axis 2
Axis 3
M code
ON
OFF : No M code
setting
ON : M code set
•
In the WITH mode, this signal turns ON when the positioning data is started, and in
the AFTER mode, this signal turns ON when the positioning data positioning is
completed.
•
This signal turns OFF with the "
Cd.14
M code OFF request".
•
When there is no M code designated (when "
Da.9
M code" is 0), this signal will
remain OFF.
•
With using continuous path control for the positioning operation, the positioning will
continue even when this signal does not turn OFF. However, a warning will occur.
(Warning code: 503)
•
When the PLC READY signal [Y1D] turns OFF, the M code ON signal will also turn
OFF.
•
If operation is started while the M code is ON, an error will occur. (Error code: 536)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание A1SD75P1-S3
Страница 2: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 3: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 16: ...A 13 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...A 20 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 25: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 275: ...MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 617: ...Index 12 MEMO Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 620: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 621: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...